NSS/CASS Salt Spray Tester
Usage:
Salt Spray Test Chambers offer the most realistic and dependable corrosion test, widely used to test corrosion resistance of automotive, paint, surface coating, chemical, aerospace, electronic, car industry, offshore and defense industries.
Standard:
DIN 50021: Salt spray testing
JIS Z2371 Methods of Salt Spray Testing
SGM-GM4465P Water Fog Humidity Test
ASTM B117 Standard Practice for Operating Salt Spray Apparatus
ASTM D1735-99 Standard Practice for Testing Water Resistance of Coatings Using Water Fog Apparatus
ASTM G85 - 11 Standard Practice for Modified Salt Spray (Fog) Testing
ISO7253:2001 Paints and varnishes – Determination of resistance to neutral salt spray (fog)
ISO9227-2012 Corrosion tests in artificial atmospheres – salt spray tests
ASTM B368-97 Standard Method for Copper-Accelerated Acetic Acid-Salt Spray (Fog) Testing (CASS Test)
ASTM B380-97(2007) Standard Test Method of Corrosion Testing of Decorative Electrodeposited Coatings by the Corrodkote Procedure.
NSS serial:
can option LED touch screen.
The whole machine adopts P.V.C material, corrosion resistance, easy to clean, no leakage phenomenon.
Using button type intelligent temperature control instrument, multiple sets of PID automatic routing,
high control precision, instrument can also be equipped with LCD touch screen.
108 l, 270 l testing machine cover adopts acrylic transparent roof, more than 480 l model adopts hard P.V.C plastic board, cover automatically opened and closed by cylinder, enclose the window light, may at any time to monitor the spray state machine and working state of the sample.
Tower spray system and device have salt liquid filter, no crystallization nozzle, spray uniform distribution, settlement free adjustment.
Sample number was laid (150 * 70 mm), such as 48 pieces can be placed in a 15 degree Angle, such as 32 can be placed in 30 degrees.
After completion of the experiment, with automatic mist device, the sample (s) can be observed clearly.
Clearance or continuous spray optional, multiple protection system, the use of safe and reliable.
CASS serial:
machine adopts imported PVC&PP hard plastic, solid structure,acid and alkali endurable, high temperature corrosion, never aging. Suitable for neutral salt fog NSS, acetic acid test along, copper acetate CASS and other experimental requirements.
Use plastic precision nozzle and conical spray, mist evenly fast, nozzle long service life, no crystallization.
Using LED LCD touch screen, can connect with computer to realize remote monitoring and operation, can be arbitrary switching in both Chinese and English.
With USB interface, can insert U disk to download historical data (the alternative recorder.
Internal control, spray time without additional time relay.
Through the flow meter, high pressure valve to regulate brine flow and pressure of compressed air, to ensure uniform settlement of salt fog.
Use the manual water system, water shortage with the function of automatically added, ensure continuity of test.
Specification list:
Model |
NSS |
SP-HL-90 |
SP-HL-120 |
SP-HL-160 |
SP-HL-200 |
CASS |
SP-AHL-90 |
SP-AHL-120 |
SP-AHL-160 |
SP-AHL-200 |
CCT |
SP-AHL-90 |
SP-AHL-120 |
SP-AHL-160 |
SP-AHL-200 |
Interior dimensions (mm) |
W |
900 |
1200 |
1600 |
2000 |
D |
600 |
850 |
1000 |
1200 |
H |
500 |
600 |
600 |
600 |
Exterior dimensions (mm) |
W |
1460 |
1900 |
2600 |
3000 |
D |
910 |
1150 |
1450 |
1650 |
H |
1280 |
1500 |
1550 |
1600 |
Chamber Tank |
270 |
480 |
800 |
1440 |
Solution Tank |
50 L |
90 |
90 |
120 |
Testing Temperature |
NSS ACSS 35℃±1℃ / CASS 50℃±1℃ |
Air Temperature |
NSS ACSS 47℃±1℃ / CASS 63℃±1℃ |
Solution Consistence |
NaCl 5% |
PH Value |
NSS (Nacl) : 6.5~7.2 / CASS(Cu / CH COOH ): 3.0~3.2 |
Temperature fluctuation |
± 0.5℃ |
Temperature uniformity |
≦2. 0℃ |
Temperature Resolution |
0.1℃ |
Spray quantum |
1.0~2.0(ml/80cm2/h) |
Chamber Material |
polyvinyl chloride (P.V.C & P.P) |
Heater |
Corrosion-resistant titanium tube |
Temperature sensor |
Platinum Resistance (PT-100) |
Safety device |
Over-temperature protection , leakage protection |
Ambient temp. & humid. range |
+5℃ ~ +35℃ / <85%RH |
Power Supply |
AC 220V/50HZ/1P AC 380V/50HZ/3P |